QL510.ADD
Appearance
| Product Support | |
|---|---|
| OS/2 1.3 | |
| OS/2 2.0 | S |
| OS/2 2.1 | S |
| OS/2 2.11 SMP | S |
| OS/2 Warp 3 | S |
| OS/2 Warp Connect | S |
| OS/2 Warp 4 | S |
| OS/2 Warp Server for e-Business | S |
SCSI adapter driver for Qlogic Fast SCSI PCI devices.
BASEDEV=QL510.ADD <parameters>
Parameters
/A:d
- Specifies which adapter (0-2) that following command line parameters apply to.
- /I
- Ignore the specified adapter (must follow "/A:d" parameter).
- /DM /!DM
- Enable/disable DASD manager support for specified adapter and/or devices (add ":d,d,d" to specify list of SCSI IDs or ":(d,d),(d,d),(d,d)" to specify ID,LUN pairs). Default is enabled.
- /SM /!SM
- Enable/disable SCSI manager support for specified adapter and/or devices (add ":d,d,d" to specify list of SCSI IDs or ":(d,d),(d,d),(d,d)" to specify ID,LUN pairs). Default is enabled.
- /!R
- Report removable disk devices to OS/2 as fixed disks. By default removable disks will be reported as removable.
/SI:d
- Specify SCSI initiator ID to use on specified adapter. Default is SCSI ID 7.
- /SR /!SR
- Enable/disable SCSI bus reset during boot on specified adapter. Default is enabled.
- /ET /!ET
- Enable/disable embedded target support for specified adapter. Default is enabled (all 8 LUNs supported). Specify /!ET for supporting LUN 0 only.
- /PAR /!PAR
- Enable/disable SCSI bus parity checking on specified adapter. Default is parity enabled.
- /SN /!SN Enable/disable synchronous negotiations for specified adapter
and/or devices (add ":d,d,d" to specify list of SCSI IDs or
":(d,d),(d,d),(d,d)" to specify ID,LUN pairs). Default is
enabled.
- /SD /!SD
- Enable/disable SCSI disconnects for specified adapter and/or devices (add ":d,d,d" to specify list of SCSI IDs or ":(d,d),(d,d),(d,d)" to specify ID,LUN pairs). Default is enabled.
- /V
- Enable verbose mode (display configuration data during boot). Default is disabled.
- /RA
- Reorder adapters. This parameter is used to reverse the order in which the Fast!SCSI PCI Basic adapters are configured.
- This parameter is required on some systems with AMI BIOS and more than one Fast!SCSI PCI Basic adapters.