Returns the modem control input signals.

Category
IOCTL_ASYNC (01h)
Function
ASYNC_GETMODEMINPUT (67h)

Parameter Packet Format

None. Packet pointer must be NULL.

Data Packet Format

Field Length C Datatype
Modem Control Input Status BYTE UCHAR
Modem Control Input Status
If a bit has a value of 1, the condition is on. If a bit has a value of 0, the condition is off.
Bit 0-3: Undefined
Bit 4: Clear To Send (CTS)
Bit 5: Data Set Ready (DSR)
Bit 6: Ring Indicator (RI)
Bit 7: Data Carrier Detect (DCD)

Returns

If the call is made with an invalid Parameter Packet value, a general failure error is reported and valid information is not returned in the Data Packet.

Remarks

If a general failure error is not returned, the physical device driver returns the current modem control input signals of the COM device.