DosMonClose
This call terminates character device monitoring. All monitor buffers associated with this process are flushed and closed.
Syntax
DosMonClose (Handle)
Parameters
- Handle (HMONITOR) - input
- Device handle returned from a previous DosMonOpen call.
Return Code
- rc (USHORT) - return
- Return code descriptions are:
- 0 - NO_ERROR
- 381 - ERROR_MON_INVALID_HANDLE
Remarks
A single process may register one or more monitors with a character device using the same device handle returned from a previous DosMonOpen call. When DosMonClose is issued for a specific, opened device handle, all monitors for the current process registered with this handle terminate.
When DosMonClose is issued, the monitor loses access to the device data stream. Before issuing DosMonClose, monitor threads calling DosMonRead and DosMonWrite should be terminated. After DosMonClose has been called:
- DosMonRead calls return an ERROR_MON_BUFFER_EMPTY return code.
- DosMonWrite calls return an ERROR_NOT_ENOUGH_MEMORY return code.
Data segments containing monitor buffers should not be freed until after DosMonClose is called. If data segments containing monitor buffers are freed before DosMonClose is called, a GP fault occurs when DosMonClose is called and the process is terminated.
For a detailed description of this call see the chapter "Character Device Monitors" in the IBM Operating System/2 Version 1.2 I/O Subsystems and Device Support Volume 1.
Bindings
C
#define INCL_DOSMONITORS USHORT rc = DosMonClose(Handle); HMONITOR Handle; /* Monitor handle */ USHORT rc; /* return code */
MASM
EXTRN DosMonClose:FAR INCL_DOSMONITORS EQU 1 PUSH WORD Handle ;Monitor handle CALL DosMonClose Returns WORD